Additionally, in some cases it is beneficial to connect two meters to a SenPulse Double rather than use two SenPulse Single devices.

...

1

2

3

4

5

6

7

8

9

GND

Tamper

Count 2

Count 1

VDD (3V)

GND

GND

TXD - to PC

RXD - from PC

Sensus meitwin

...

Connection

  1. Remove the lid of the box by unscrewing the 4 screws on top

  2. Unscrew the cap of the gland and remove the rubber grommet found inside.

  3. Pass the cap of the gland through the water meter cable and then pass the rubber grommet afterwards.

  4. Pass the cable of the meter through the gland into the inside of the box.

  5. Now that the wires are inside the package they are to be connected to the board through the green connector. Hold down connector buttons to open and release the individual connections. Connect wires according to the figure below.

...