Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

We recommend configuring your device by downlink next.

...

Elster V210

...

Info

The k: 1:1 at the top right of the device indicates the number of liters per pulse. e.g. 1 liter to 1 pulse.

...

We recommend configuring your device by downlink next.

...

Sensus MeiTwin 50

Some water flow rates vary enough that double water meters are employed, One that is capable of higher precision and one that is for higher flow rates.

Additionally, in some cases it is beneficial to connect two meters to a SenPulse Double rather than use two SenPulse Single devices.

...

1

2

3

4

5

6

7

8

9

GND

Tamper

Count 2

Count 1

VDD (3V)

GND

GND

TXD - to PC

RXD - from PC

Sensus meitwin

...

Connection

  1. Remove the lid of the box by unscrewing the 4 screws on top

  2. Unscrew the cap of the gland and remove the rubber grommet found inside.

  3. Pass the cap of the gland through the water meter cable and then pass the rubber grommet afterwards.

  4. Pass the cable of the meter through the gland into the inside of the box.

  5. Now that the wires are inside the package they are to be connected to the board through the green connector. Hold down connector buttons to open and release the individual connections. Connect wires according to the figure below.

...

  • Count 1 logs each pulse from one of the water meters and Count 2 the other meter.

Elster V100

...

Connection

  1. Remove the lid of the box by unscrewing the 4 screws on top

  2. Unscrew the cap of the gland and remove the rubber grommet found inside.

  3. Pass the cap of the gland through the water meter cable and then pass the rubber grommet afterwards.

  4. Pass the cable of the meter through the gland into the inside of the box.

  5. Now that the wires are inside the package they are to be connected to the board through the green connector. Hold down connector buttons to open and release the individual connections. Connect wires according to the figure below.

Image Added

Blue/Black

Yellow

Empty

Red

Red

Black

GND (Left)

Tamper

Direction

Count 1

3.3V

GND (Right)

Filter by label (Content by label)
showLabelsfalse
max5
spacescom.atlassian.confluence.content.render.xhtml.model.resource.identifiers.SpaceResourceIdentifier@957
showSpacefalse
sortmodified
typepage
reversetrue
labelsplatform
cqllabel = in ( "device-general" , "device" ) and type = "page" and space = "KB"
Page Properties
hiddentrue

Status

Status
colourGreen
titleIn Progresspublished

Notes

Remove datasheet snippets and include a reference to the pinout of the Sendeca.?

link to a Use Case?.